Dampers are used to adjust the distribution of §airflows in duct systems. The common (i.e., most §commonly used) method is to adjust each damper in §turn so that the airflow through its branch equals §the desired level. Typically ... celý popis

50.29

Bežne: 52.91 €

Ušetríte 2.62 €


U vydavateľa na objednávku
Odosielame za 3 - 5 dní
Pridať medzi želanie

Mohlo by sa vám tiež páčiť

Darčekový poukaz: Radosť zaručená
  1. Darujte poukaz v ľubovoľnej hodnote, a my sa postaráme o zvyšok.
  2. Poukaz sa vzťahuje na všetky produkty v našej ponuke.
  3. Elektronický poukaz si vytlačíte z e-mailu a môžete ho ihneď darovať.
  4. Platnosť poukazu je 12 mesiacov od dátumu vystavenia.

Objednať darčekový poukazViac informácií

Viac informácií o knihe Balancing Exhaust Ventilation Systems

Nákupom získate 124 bodov

Anotácia knihy

Dampers are used to adjust the distribution of §airflows in duct systems. The common (i.e., most §commonly used) method is to adjust each damper in §turn so that the airflow through its branch equals §the desired level. Typically, the airflow through §each branch duct is estimated from the centerline §velocity pressure. To test the effectiveness of that §approach, dampers were adjusted on a seven branch, §full-sized experimental duct system. After adjusting §the dampers for a given condition, the percent §excess airflow (%Qexcess) for the system was §estimated as the amount above the ideal fan airflow §that would exist if the fan speed were adjusted so §that the lowest ratio of airflow to airflow goal for §any branch was unity. The lower the value of percent §excess airflow, the more perfectly balanced the §system was. The results varied with the level of the §target airflows. The excess airflow values were much §higher than the airflow values found by Dodrill §(2004) on the same system for the SPh Goal Ratio §method proposed by Guffey (2005). This analysis §should be useful to professionals in the fields of §HVAC and ventilation design.

Parametre knihy

50.29

Obľúbené z iného súdka



Osobný odber Bratislava a 2642 dalších

Copyright ©2008-24 najlacnejsie-knihy.sk Všetky práva vyhradenéSúkromieCookies


Môj účet: Prihlásiť sa
Všetky knihy sveta na jednom mieste. Navyše za skvelé ceny.

Nákupný košík ( prázdny )

Vyzdvihnutie v Zásielkovni
zadarmo nad 59,99 €.

Nachádzate sa: