Effect of flow diverting stents on intracranial artery bifurcations with a focus on bifurcating vessels diameter on hemodynamics and occlusion / Najlacnejšie knihy
Effect of flow diverting stents on intracranial artery bifurcations with a focus on bifurcating vessels diameter on hemodynamics and occlusion

Kód: 02890682

Effect of flow diverting stents on intracranial artery bifurcations with a focus on bifurcating vessels diameter on hemodynamics and occlusion

Autor Sarthak Khandelwal

Bachelor Thesis from the year 2015 in the subject Engineering - Mechanical Engineering, grade: 69%, University of Sheffield, language: English, abstract: An intracranial aneurysm is a vascular disorder estimated to affect up to 5% ... celý popis

64.30


Skladom u dodávateľa
Odosielame za 14 - 18 dní
Pridať medzi želanie

Mohlo by sa vám tiež páčiť

Darčekový poukaz: Radosť zaručená
  1. Darujte poukaz v ľubovoľnej hodnote, a my sa postaráme o zvyšok.
  2. Poukaz sa vzťahuje na všetky produkty v našej ponuke.
  3. Elektronický poukaz si vytlačíte z e-mailu a môžete ho ihneď darovať.
  4. Platnosť poukazu je 12 mesiacov od dátumu vystavenia.

Objednať darčekový poukazViac informácií

Viac informácií o knihe Effect of flow diverting stents on intracranial artery bifurcations with a focus on bifurcating vessels diameter on hemodynamics and occlusion

Nákupom získate 159 bodov

Anotácia knihy

Bachelor Thesis from the year 2015 in the subject Engineering - Mechanical Engineering, grade: 69%, University of Sheffield, language: English, abstract: An intracranial aneurysm is a vascular disorder estimated to affect up to 5% of the global population. The use of flow diverting stents for treatment of intracranial aneurysms leads to ischemic complications. It is hypothesized that alteration in hemodynamics after placement of stents plays a vital role in ischemia (vessel occlusion). This project uses Computational Fluid Dynamics to study the alterations in hemodynamics before and after placement of stent with respect to the relative diameter of the bifurcating arteries on idealized geometries using ANSYS-CFX 15.0. Pressure and flow rate waveforms were extracted from a 1D model of the arterial tree to simulate hemodynamic conditions correctly. The results show that there are significant changes in hemodynamics (pressure and wall shear stress) before and after placement of stent. These changes are also affected by the relative diameters of the bifurcating arteries. The trends observed in hemodynamics can be interpreted by clinicians to study vessel occlusion and its relation to the relative diameters of arteries. The results have a potential to assist in treatment of aneurysms without ischemic complications.

Parametre knihy

Zaradenie knihy Knihy po anglicky Technology, engineering, agriculture Technology: general issues Engineering: general

64.30

Obľúbené z iného súdka



Osobný odber Bratislava a 2642 dalších

Copyright ©2008-24 najlacnejsie-knihy.sk Všetky práva vyhradenéSúkromieCookies


Môj účet: Prihlásiť sa
Všetky knihy sveta na jednom mieste. Navyše za skvelé ceny.

Nákupný košík ( prázdny )

Vyzdvihnutie v Zásielkovni
zadarmo nad 59,99 €.

Nachádzate sa: