This experiment explored the ability of a row of cylindrical dimples' vortex shedding to entrain the cooling film in the boundary layer for longer distances, thus enhancing cooling on a turbine leading edge model. The experiment u ... celý popis

69.36


Skladom u dodávateľa
Odosielame za 14 - 18 dní
Pridať medzi želanie

Mohlo by sa vám tiež páčiť

Darčekový poukaz: Radosť zaručená
  1. Darujte poukaz v ľubovoľnej hodnote, a my sa postaráme o zvyšok.
  2. Poukaz sa vzťahuje na všetky produkty v našej ponuke.
  3. Elektronický poukaz si vytlačíte z e-mailu a môžete ho ihneď darovať.
  4. Platnosť poukazu je 12 mesiacov od dátumu vystavenia.

Objednať darčekový poukazViac informácií

Viac informácií o knihe Experimental Investigation of the Effect of Dimples on Turbine Adiabatic Film Cooling

Nákupom získate 172 bodov

Anotácia knihy

This experiment explored the ability of a row of cylindrical dimples' vortex shedding to entrain the cooling film in the boundary layer for longer distances, thus enhancing cooling on a turbine leading edge model. The experiment utilized a semi-cylindrical leading edge followed by an after body with straight surfaces. A foam leading edge drilled with cooling holes allowed for a determination of adiabatic film effectiveness using an Infrared Thermography (IR) technique to measure surface temperature distributions. Two test models were utilized, one with a row of seven dimples placed upstream from the cooling-hole, while the other model had a row of seven downstream. Five blowing ratios were tested: 0.5, 0.75, 1.0, 1.25, and 1.5. It was observed that the dimples introduced disturbances in the boundary layer that encouraged vertical and lateral diffusion of the cooling film that caused reattachment of coolant jet liftoff. Dimples placed upstream of the cooling hole improved spanwise averaged adiabatic film cooling effectiveness by up to 60% for far downstream locations. Dimples placed downstream of the cooling hole enhanced ?? up to 30% for far downstream locations.

Parametre knihy

Zaradenie knihy Knihy po anglicky Society & social sciences Education

69.36

Obľúbené z iného súdka



Osobný odber Bratislava a 2642 dalších

Copyright ©2008-24 najlacnejsie-knihy.sk Všetky práva vyhradenéSúkromieCookies


Môj účet: Prihlásiť sa
Všetky knihy sveta na jednom mieste. Navyše za skvelé ceny.

Nákupný košík ( prázdny )

Vyzdvihnutie v Zásielkovni
zadarmo nad 59,99 €.

Nachádzate sa: