Metastable Technetium 99-labeled Methoxy-IsoButyl-Isonitrile (99mTc-MIBI) single-photon emission computed tomography (SPECT/CT) is recommended for the preoperative workup of hyperparathyroidism to guide minimally invasive surgery. ... celý popis

49.53


Skladom u dodávateľa
Odosielame za 14 - 18 dní
Pridať medzi želanie

Mohlo by sa vám tiež páčiť

Darčekový poukaz: Radosť zaručená
  1. Darujte poukaz v ľubovoľnej hodnote, a my sa postaráme o zvyšok.
  2. Poukaz sa vzťahuje na všetky produkty v našej ponuke.
  3. Elektronický poukaz si vytlačíte z e-mailu a môžete ho ihneď darovať.
  4. Platnosť poukazu je 12 mesiacov od dátumu vystavenia.

Objednať darčekový poukazViac informácií

Viac informácií o knihe Hybrid SPECT/CT imaging with 99mTc-MIBI

Nákupom získate 123 bodov

Anotácia knihy

Metastable Technetium 99-labeled Methoxy-IsoButyl-Isonitrile (99mTc-MIBI) single-photon emission computed tomography (SPECT/CT) is recommended for the preoperative workup of hyperparathyroidism to guide minimally invasive surgery. Nevertheless, the introduction of a CT scan, even at low dose, increases the total radiation dose delivered to the patient. The aim was to evaluate the additional effective dose delivered by CT to 99mTc-MIBI parathyroid scintigraphy. This prospective study included 100 adults with primary hyperparathyroidism who received 99mTc-MIBI SPECT/CT. The mean age was 55.6 years with a M/F sex ratio of 0.28. The effective scintigraphic dose was 9.77 mSv. The mean CT effective dose was 1.77mSv. The mean total effective dose from the hybrid examination was 11.54 mSv and ranged from 10.66 to 12.88 mSv. The contribution of the additional radiation induced by CT ranged from 8.3 to 24.1% with a mean of 15%. This dose is not negligible. But taking into account the benefit of hybrid imaging, this additional radiation is still justifiable.

Parametre knihy

Zaradenie knihy Knihy po nemecky Naturwissenschaften, Medizin, Informatik, Technik Medizin Nichtklinische Fächer

49.53

Obľúbené z iného súdka



Osobný odber Bratislava a 2642 dalších

Copyright ©2008-24 najlacnejsie-knihy.sk Všetky práva vyhradenéSúkromieCookies


Môj účet: Prihlásiť sa
Všetky knihy sveta na jednom mieste. Navyše za skvelé ceny.

Nákupný košík ( prázdny )

Vyzdvihnutie v Zásielkovni
zadarmo nad 59,99 €.

Nachádzate sa: