Autor Ahmad Shahsiah

Dissolved Gas Analysis is one of the best known §methods to detect incipient faults in power §transformers. Characteristic gases for power §transformers are defined in IEC 60599. However, §these gases migrate between the transform ... celý popis

63.69


Skladom u dodávateľa
Odosielame za 14 - 18 dní
Pridať medzi želanie

Mohlo by sa vám tiež páčiť

Darčekový poukaz: Radosť zaručená
  1. Darujte poukaz v ľubovoľnej hodnote, a my sa postaráme o zvyšok.
  2. Poukaz sa vzťahuje na všetky produkty v našej ponuke.
  3. Elektronický poukaz si vytlačíte z e-mailu a môžete ho ihneď darovať.
  4. Platnosť poukazu je 12 mesiacov od dátumu vystavenia.

Objednať darčekový poukazViac informácií

Viac informácií o knihe Mass Transfer in Electrical Insulation of Power Transformers

Nákupom získate 157 bodov

Anotácia knihy

Dissolved Gas Analysis is one of the best known §methods to detect incipient faults in power §transformers. Characteristic gases for power §transformers are defined in IEC 60599. However, §these gases migrate between the transformer liquid §and solid insulation due to temperature variations; §this could potentially cause errors in the fault §detection method. Little analytical or experimental §work has been performed to date on the temporal §nature of this problem.§§The suggested dynamic model in this book is based on §the process of diffusion. The steady-state §information extracted from experiments is compared §with findings obtained from the literature. The §final dynamic model is tested against experiments.§§The results show that the migration phenomenon in §the liquid-solid insulation of power transformers §can be explained by diffusion equations. Other §findings include diffusion coefficients and steady-§state information of the characteristic gases in the §transformer insulation system. This text is suitable §for researchers who work in the area of fault §detection in high voltage fluid-filled equipment or §students who are interested in mass transport §phenomena. Dissolved Gas Analysis is one of the best known §methods to detect incipient faults in power §transformers. Characteristic gases for power §transformers are defined in IEC 60599. However, §these gases migrate between the transformer liquid §and solid insulation due to temperature variations; §this could potentially cause errors in the fault §detection method. Little analytical or experimental §work has been performed to date on the temporal §nature of this problem.§The suggested dynamic model in this book is based on §the process of diffusion. The steady-state §information extracted from experiments is compared §with findings obtained from the literature. The §final dynamic model is tested against experiments.§The results show that the migration phenomenon in §the liquid-solid insulation of power transformers §can be explained by diffusion equations. Other §findings include diffusion coefficients and steady-§state information of the characteristic gases in the §transformer insulation system. This text is suitable §for researchers who work in the area of fault §detection in high voltage fluid-filled equipment or §students who are interested in mass transport §phenomena.

Parametre knihy

Zaradenie knihy Knihy po anglicky Technology, engineering, agriculture Energy technology & engineering Electrical engineering

63.69

Obľúbené z iného súdka



Osobný odber Bratislava a 2642 dalších

Copyright ©2008-24 najlacnejsie-knihy.sk Všetky práva vyhradenéSúkromieCookies


Môj účet: Prihlásiť sa
Všetky knihy sveta na jednom mieste. Navyše za skvelé ceny.

Nákupný košík ( prázdny )

Vyzdvihnutie v Zásielkovni
zadarmo nad 59,99 €.

Nachádzate sa: