Remote Quantification of Smokestack Total Effluent Mass Flow Rates Using Imaging Fourier-Transfrom Spectroscopy

Autor Jacob Harley

A Telops Hyper-Cam midwave infrared (1.5 - 5.5µm) imaging Fourier-transform spectrometer (IFTS) was used to estimate industrial smokestack total effluent mass flow rates by combining spectrally-determined species concentrations wi ... celý popis

69.52


Skladom u dodávateľa
Odosielame za 14 - 18 dní
Pridať medzi želanie

Mohlo by sa vám tiež páčiť

Darčekový poukaz: Radosť zaručená
  1. Darujte poukaz v ľubovoľnej hodnote, a my sa postaráme o zvyšok.
  2. Poukaz sa vzťahuje na všetky produkty v našej ponuke.
  3. Elektronický poukaz si vytlačíte z e-mailu a môžete ho ihneď darovať.
  4. Platnosť poukazu je 12 mesiacov od dátumu vystavenia.

Objednať darčekový poukazViac informácií

Viac informácií o knihe Remote Quantification of Smokestack Total Effluent Mass Flow Rates Using Imaging Fourier-Transfrom Spectroscopy

Nákupom získate 172 bodov

Anotácia knihy

A Telops Hyper-Cam midwave infrared (1.5 - 5.5µm) imaging Fourier-transform spectrometer (IFTS) was used to estimate industrial smokestack total effluent mass flow rates by combining spectrally-determined species concentrations with flow rates estimated via analysis of sequential images in the raw interferogram cube. Strong emissions from H2O, CO2, CO, SO2, and NO were observed in the spectrum. A previously established plume radiative transfer model was used to estimate gas concentrations, and a simple temporal cross-correlation analysis of sequential imagery enabled an estimation of the flow velocity. Final effluent mass flow rates for CO2 and SO2 of 13.5 3.78 kg/s and 71.3 19.3 g/s were in good agreement with in situ rates of 11.6 0.07 kg/s and 67.8 0.52 g/s. NO was estimated at 16.1 4.19 g/s, which did not compare well to the total NOx (NO + NO2) reported value of 11.2 0.16 g/s. Unmonitored H2O, HCl, and CO were also estimated at 7.76 2.25 kg/s, 7.40 2.00 g/s, and 15.0 4.05 g/s respectively.

Parametre knihy

Zaradenie knihy Knihy po anglicky Society & social sciences Education

69.52

Obľúbené z iného súdka



Osobný odber Bratislava a 2642 dalších

Copyright ©2008-24 najlacnejsie-knihy.sk Všetky práva vyhradenéSúkromieCookies


Môj účet: Prihlásiť sa
Všetky knihy sveta na jednom mieste. Navyše za skvelé ceny.

Nákupný košík ( prázdny )

Vyzdvihnutie v Zásielkovni
zadarmo nad 59,99 €.

Nachádzate sa: