Synthesis & characterization new polymers as stationary phase in HPLC / Najlacnejšie knihy
Synthesis & characterization new polymers as stationary phase in HPLC

Kód: 09924261

Synthesis & characterization new polymers as stationary phase in HPLC

Autor Ali Noor M, Bakir Emaad T, Nassori Nabil S

New method for measured the hypertension drugs by one run in HPLC. Two cross like polymer were prepared. first polymer was synthesized by condensation reaction between glycerol triethanol amine with maleic anhydride. The second po ... celý popis

87.57


Skladom u dodávateľa
Odosielame za 14 - 18 dní
Pridať medzi želanie

Mohlo by sa vám tiež páčiť

Darčekový poukaz: Radosť zaručená
  1. Darujte poukaz v ľubovoľnej hodnote, a my sa postaráme o zvyšok.
  2. Poukaz sa vzťahuje na všetky produkty v našej ponuke.
  3. Elektronický poukaz si vytlačíte z e-mailu a môžete ho ihneď darovať.
  4. Platnosť poukazu je 12 mesiacov od dátumu vystavenia.

Objednať darčekový poukazViac informácií

Viac informácií o knihe Synthesis & characterization new polymers as stationary phase in HPLC

Nákupom získate 216 bodov

Anotácia knihy

New method for measured the hypertension drugs by one run in HPLC. Two cross like polymer were prepared. first polymer was synthesized by condensation reaction between glycerol triethanol amine with maleic anhydride. The second polymer was synthesized by addition polymerization of free radical for acrylamide, bisacrylamide with ammonium persulphate and TEMED. The products and used as stationary phase for HPLC. This stationary phase has been packed into stainless steel column. The chromatographic performances of the newly packed columns are characterized.N,H, and were measured. Amiloride, furosmide, and atenolol were separated with 1st column gradient eluention of (0-20)% pH 8 with methanol and 2nd column gradient eluention of (0-10)% pH 6. Furthermore tyrosine, Tryptophane and Phenylalanine were also examined with 1st column with isocratic eluention 15% pH 6 in 85 ethanol and 2nd column gradient eluention (0-15)% pH 6 in ethanol .Vitamin E was also using 1st column column and 100% acetonitrile.The separation of these compounds on these two columns was compared with their separation on C-18 commercial column

Parametre knihy

Zaradenie knihy Knihy po anglicky Society & social sciences Psychology

87.57

Obľúbené z iného súdka



Osobný odber Bratislava a 2642 dalších

Copyright ©2008-24 najlacnejsie-knihy.sk Všetky práva vyhradenéSúkromieCookies


Môj účet: Prihlásiť sa
Všetky knihy sveta na jednom mieste. Navyše za skvelé ceny.

Nákupný košík ( prázdny )

Vyzdvihnutie v Zásielkovni
zadarmo nad 59,99 €.

Nachádzate sa: