CHRONICALLY IMPLANTABLE SU8 BASED NEURAL PROBES / Najlacnejšie knihy
CHRONICALLY IMPLANTABLE SU8 BASED NEURAL PROBES

Kód: 06825861

CHRONICALLY IMPLANTABLE SU8 BASED NEURAL PROBES

Autor Sung Hoon Cho

Various types of SU-8 based microprobes were proposed, fabricated and optimized to record action potentials from the regenerated nerves. The shape and the fabrication process of the 3-D standing microprobe were relatively simple, ... celý popis

50.21

Bežne: 52.83 €

Ušetríte 2.62 €


U vydavateľa na objednávku
Odosielame za 3 - 5 dní
Pridať medzi želanie

Mohlo by sa vám tiež páčiť

Darčekový poukaz: Radosť zaručená
  1. Darujte poukaz v ľubovoľnej hodnote, a my sa postaráme o zvyšok.
  2. Poukaz sa vzťahuje na všetky produkty v našej ponuke.
  3. Elektronický poukaz si vytlačíte z e-mailu a môžete ho ihneď darovať.
  4. Platnosť poukazu je 12 mesiacov od dátumu vystavenia.

Objednať darčekový poukazViac informácií

Viac informácií o knihe CHRONICALLY IMPLANTABLE SU8 BASED NEURAL PROBES

Nákupom získate 124 bodov

Anotácia knihy

Various types of SU-8 based microprobes were proposed, fabricated and optimized to record action potentials from the regenerated nerves. The shape and the fabrication process of the 3-D standing microprobe were relatively simple, but there were difficulties in fabricating electrodes and wire interconnection. The planar microprobe also had difficulties in wire interconnection. The straight and J-shaped probes were devised and fabricated. The channel structure was designed to guide the regenerated axons to be placed on the surface of the gold electrode and capture spike signals from the regenerated axons. The gold pads and holes were also devised for wire interconnection, and flexible wings were added to the probe body for stability. Satisfactory results were achieved in the biocompatibility tests. The probes were wired and implanted into the BNRG that was filled with NGF. The BNRG was implanted near the amputated peripheral nerve of a laboratory rat, and spike signals from the regenerated axons were successfully detected. The microprobes have detected spike signals consistently with stability for more than 6 months.

Parametre knihy

50.21

Obľúbené z iného súdka



Osobný odber Bratislava a 2642 dalších

Copyright ©2008-24 najlacnejsie-knihy.sk Všetky práva vyhradenéSúkromieCookies


Môj účet: Prihlásiť sa
Všetky knihy sveta na jednom mieste. Navyše za skvelé ceny.

Nákupný košík ( prázdny )

Vyzdvihnutie v Zásielkovni
zadarmo nad 59,99 €.

Nachádzate sa: