Flat Plate Multi Storied Frames with and without RC Infilled Walls / Najlacnejšie knihy
Flat Plate Multi Storied Frames with and without RC Infilled Walls

Kód: 14445812

Flat Plate Multi Storied Frames with and without RC Infilled Walls

Autor P. M. B. Raj Kiran Nanduri, Dean Kumar Boda

In high rise buildings Flat plate floor structures are uncertain in resisting lateral loads. Hence lateral load resisting systems like Braced walls, outriggers, structural walls like RC Infill Walls and shear walls are to be provi ... celý popis

53.33


Skladom u dodávateľa
Odosielame za 8 - 10 dní
Pridať medzi želanie

Mohlo by sa vám tiež páčiť

Darujte túto knihu ešte dnes
  1. Objednajte knihu a vyberte Zaslať ako darček.
  2. Obratom obdržíte darovací poukaz na knihu, ktorý môžete ihneď odovzdať obdarovanému.
  3. Knihu zašleme na adresu obdarovaného, o nič sa nestaráte.

Viac informácií

Viac informácií o knihe Flat Plate Multi Storied Frames with and without RC Infilled Walls

Nákupom získate 132 bodov

Anotácia knihy

In high rise buildings Flat plate floor structures are uncertain in resisting lateral loads. Hence lateral load resisting systems like Braced walls, outriggers, structural walls like RC Infill Walls and shear walls are to be provided. In the present work a comparative study has been conducted with respect to the height of the RC framed structure i.e. number of storeys of the RC framed structure such as 20 storey, 40 storey, 60 storey and 80 storey are analyzed using STAAD.PRO(V8i) software. For each of these structures three comparisons have been made; one comparison is Conventional Beam supported slab structure compared with Flat Plate RC Framed structure, Flat Plate Framed structure compared with Flat Plate Framed structure having external peripheral RC Infill Wall and Conventional Beam supported slab Framed structure compared with Flat Plate Framed structure having external peripheral RC Infill Wall.In these comparisons the Critical Column Axial Forces, Critical Column moments due to gravity and wind loads and Lateral Drift (in mm) in X, Z direction due to Wind loads are observed. Basic wind speed of 44 m/s is considered for these structures located at Hyderabad, INDIA.

Parametre knihy

53.33

Obľúbené z iného súdka



Osobný odber Bratislava a 2642 dalších

Copyright ©2008-24 najlacnejsie-knihy.sk Všetky práva vyhradenéSúkromieCookies


Môj účet: Prihlásiť sa
Všetky knihy sveta na jednom mieste. Navyše za skvelé ceny.

Nákupný košík ( prázdny )

Vyzdvihnutie v Zásielkovni
zadarmo nad 59,99 €.

Nachádzate sa: